Installation
This section offers step-by-step instructions for installing the TPT101 Twisted Pair Transmitter
and the TPR101 Twisted Pair Receiver. Application Diagrams are provided on pages 9 - 11.
Installation of the TPT101 / TPR101 System must only be carried out by
qualified technicians.
Note: Read the instructions carefully before initiating the installation procedure. Make sure that
there is no power connected to any of the units and that the TPR101 power switch is off.
1.) Install the Junction Box - in accordance to the standards set forth in the National Electrical
Code. The TPT101 can also be installed in an existing 1-gang junction box (see Dimensions
Diagram on page 18). You may also install the TPT101 in any desired wall location using an
optional IN9181 wall-mounting bracket.
Important Safety Issue: When dealing with long cable runs, it is possible
that you will encounter different grounding potentials throughout the facility.
It is very important to connect the grounding terminal on the back of the
TPT101 to local earth ground to prevent possible electrical shock.
2.) Place / Install the TPR101 at the Desired Location - Make sure that the unit is seated on a
flat surface or is securely installed in a standard 19” equipment rack using an optional IN9080
rack shelf. When attaching any INLINE unit to an INLINE rack mount shelf, the four (4)
rubber feet must
be removed from the bottom of the unit. Secure the TPR101 to the rack
mount shelf using two (2) #6 - 32 x ¼” long screws (provided with the rack shelf). Two
TPR101 Twisted Pair Receivers can be mounted side-by-side on a single rack shelf, or a
single unit may be mounted along with an optional IN9088B blank plate. Together, the
TPR101 and the IN9088B fit snugly in a 1U rack space. The unit can also be mounted to
virtually any flat surface using the optional IN9252 table mounting brackets.
3.) Set the TPT101 / TPR101 switches as appropriate for your installation and run one or
two CAT5 cables between the TPT101 / TPR101. The TPT101 transmitter and TPR101
receiver can be linked with either one or two CAT5 cables depending on the desired signal
and power configuration:
Configuration A - Single CAT5 Link: RGBHV Video Only (no audio) with Remote
Power for TPT101 - (See Application Diagram A on page 9 and Control / Connector
Diagrams on Pages 13 & 14)
TPT101 Switch: Set the Power switch on the rear of the TPT101 to REMOTE.
TPR101 Switches: Set the Link A Mode switch (located on the left rear of the
TPR101) to the REMOTE POWER position.
CAT5 Cable Connection: Connect one end of the CAT5 cable to the LINK A
VIDEO Output Port on the rear of the TPT101, and the other end to the LINK A
Input Port on the rear of the TPR101.
Do not
connect a local power supply to the TPT101.