This guide provides procedures for setting up and configuring the Extron RCP 2000 Remote Control Panel with ISS 506
Support.
IP Setup
The RCP 2000 is delivered with a factory default IP address of 192.168.254.253. If you want to change this address, or need
to enter other information required for Ethernet or serial communication, follow these steps:
1. Press the Color/Tint, Cont/Bright,
Size, and Center picture control
buttons simultaneously and hold them
until the Cut button lights (about
2 seconds). The RCP's MAC address is
displayed on the LCD screen.
2. Press the Cut or Take button repeatedly to
step through the IP Setup menu options to
access the item to be changed.
3. If adjusting one of the four IP settings (RCP
IP address, switcher IP address, subnet
mask, or Gateway), press the Color/Tint,
Cont/Bright, Size, or Center button to select
an address block (octet) to change. The
selected octet on the LCD screen blinks.
4. Rotate the H Adjust knob to change the
selected value.
5. When finished, press the Detail button to save the configuration and exit IP Setup.
Press
Default
Cycle
CUT
Press
CUT
Step
1
Step
3
Step
5
Press
CUT
Press Color/Tint, Cont/Bright, Size,
and Center and hold for 2 sec.
Rotate the H knob to change
the selected IP address
segment, set the baud rate,
or turn DHCP on and off.
Press each Picture Control
button to select the next IP
address segment.
Step
2
Step
4
A6-00-B7
00-0F-2B
Press the Detail button
to save the configuration
and exit IP Setup.
CENTER
SIZE
CONT
BRIGHT
COLOR
TINT
I 010.056
P142.008
MAC address
RCP’s IP address
S010.056
I 003.212
Switcher’s IP
S255.255
M255.000
Subnet mask
Press
CUT
DHCP
Off
CENTER
SIZE
CONT
BRIGHT
COLOR
TINT
Select
1st octet
Select
3rd octet
Select
2nd octet
Select
4th octet
H
000-255
G010.056
M000.100
Gateway IP
RCP Baud
9600
Press
CUT
Press
CUT
Press
CUT
Sw Baud
9600
Press
CUT
H
9600-115,200
H
9600-115,200
Press the Cut button to cycle through
the IP Setup menu options.
Press simultaneously.
DETAIL
68-1608-01 Rev. A
08 08
RCP 2000 with ISS 506 Support
Setup Guide
2 3 4 5 6 7 8
CUT
CONT
BRIGHT
H
V
COLOR
TINT
WIPE
DISSOLVE
TAKE
2 3 4 5 6 7 8
PROGRAM
ADJUST
PICTURE CONTROLS
PREVIEW
ION
LOGO 1
/BLACK
LOGO 2
/BLACK
LOGO 1
/BLACK
LOGO 2
/BLACK
SIZE CENTER DETAIL
AUTO
IMAGE
Press and hold
all four buttons.
The CUT button lights.
A6-00-B7
00-0F-2B
After 2 seconds,
the display shows
the MAC address.
01 = Dissolve (PIP only) 10 = S
02 = Soft Right 11 = S
03 = Soft Left 12 = S
04 = Soft Up 13 = S
05 = Soft Down 14 =
06 = Soft Center In 15 =
07 = Soft Center Out 16 =
08 = Soft Curtain In 17 =
09 = Soft Curtain Out
Wipe an
Step
1
Vue de la page 0
1 2 3 4

Résumé du contenu

Page 1 - Setup Guide

This guide provides procedures for setting up and configuring the Extron RCP 2000 Remote Control Panel with ISS 506 Support. IP SetupThe RCP 2000 is d

Page 2 - I 000.000

RCP 2000 with ISS 506 Support • Setup Guide2RCP 2000 with ISS 506 Support Setup Guide (cont'd)RS-232 SetupTo configure an RS-232 connection to the

Page 3 - Selecting a dissolve

Selecting a cut (full screen program/preview swap)To select a full screen cut transition (immediate and seamless replacement of the program image with

Page 4 - 2 3 4 5 6 7 8

© 2008 Extron Electronics. All rights reserved.Other Button ControlsThe following additional functions are accessed via the Program and/or Preview b