If the Image is Not Displayed Correctly
1. If the output image looks too green, the sync on green (SOG) DIP switch (switch 2)
may be set to On (up), and the display device may not be configured to handle SOG
signals. Set the switch to Off (down).
2. If the picture bends or flags at the top of the screen, set the serration pulse DIP
switch (switch 3) to Off (down).
3. For a display device that experiences intermittent glitches, try changing the DDSP setting
using DIP switch 1.
4. If the picture “hangs off” the edges of the screen, adjust the centering controls
(
[
,
{
).
5. If the edges of the image seem to exceed their boundaries or if thin lines and sharp
edges look thick and fuzzy, try changing the Level/Boost or Peak Control settings. If
the image is too bright, decrease the boost or peaking level.
6. If using the EDID Minder model, make sure the rotary dial and two position
(frequency) DIP switch are set to the correct values. If these settings are changed,
reboot the source device.
7. If using the EDID Minder model, make sure the video output can support the resolution
provided by the EDID Minder. If necessary reset the rotary dial and reboot the source
device.
8. If the image still does not display correctly, call the Extron S3 Sales and Technical Support
Hotline (see the phone numbers listed on the back page of this guide).
If the Interface Does Not Respond to Controls
1. If you cannot adjust the horizontal (
[
knob) or vertical (
{
knob) centering, DDSP
may be in use. Ensure that DIP switch 1 (DDSP) on the rear panel is Off (down).
2. If you cannot shift between inputs (input selection switch) or adjust the horizontal
(
[
knob) or vertical (
{
knob) centering from the front panel, but you can operate
the interface via a remote control, the interface may be in front panel security lockout
(executive mode). Toggle executive mode off (see Front Panel Security Lockout on
page 16).
If the Image is Not Correctly Centered
If the picture from a new source computer does not seem correctly centered, the input
position memory presets might require resetting. Reset the input position memories as
follows:
1. Unplug the AC power cord from the interface.
2. Hold the input selection switch up while you plug in the AC power cord to the interface
and wait approximately 5 seconds.
3. Select the appropriate input and adjust the horizontal and vertical centering.
If Auto Switching Does Not Work
Auto switch works for RGBHV and RGBS video inputs only. Auto switch does not work for
RGsB video input.
NOTE: The selection of RGsB video output on rear panel DIP switch 2 has no effect on
auto switching.