SCS 300 • Installation, Connection, and Settings
2-10
Installation, Connection, and Settings, cont’d
Up position = On
Down = Off
Default = all Off
Front Panel DIP Switch Settingsettings
The bank of eight DIP switches allows the user to control sync
input termination, sync polarity, output sync format, and
serration pulses, or to disable all sync processing. Switches
furthest to the right takes the highest priority. Set each switch as
desired, in the order they are listed:
INPUT SYNC 10K
FORCE NEG SYNC
COMP SYNC OUT
SOG OUT
RsGsBs OUT
SERR REMOVAL
NO SYNC PROC
SPARE
ON
OFF
ON
1 2 3 4 5 6 7 8
Settings for the DIP switches on the SCS 300:
Switch 1: On = 10k ohm sync input termination
Off = 510 ohm sync input termination
Switch 2: On = Force negative sync polarity on output
Off = Sync polarity follows input
Switch 3: On = Enable composite sync output
Off = Disable composite sync output
Switch 4: On = Sync on green output
Off = Disable sync on green output
Switch 5: On = Enable RsGsBs (sync on all)
Off = Disable RsGsBs
N
When switch #s 3, 4, and 5 are in the off position,
Horizontal and Vertical sync is on.
Switch 6 On = Disable (remove) serration pulses
Off = Enable (pass) serration pulses
Switch 7: On = Disables sync processing
Off = Normal sync processing
N
If switch #7 is in the on position, it disables all switches
except for switch #1, and deactivates all sync processing
and timing changes. However, sync edges will still be
reshaped.
Switch 8: Spare