Extron electronics 3G-AE 100 Guide de l'utilisateur Page 8

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 13
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 7
3G-AE 100 • Panels and Cabling 3
CH 5 CH 6 CH 7 CH 8
CH 1 CH 2 CH 3 CH 4
3G/HD
SD-SDI
3G-AE
100
LOOP
THROUGH
INPUT ANALOG OUTPUTS
GROUP
SELECT
SPARE
1
1/2
3/4
2
ON
12V
0.8A MAX
POWER
1
2 3
4
5
Figure 2. 3G-AE 100 Rear Panel
a Power input — Wire the power supply as shown in figure 3, and connect it to the
power connector.
SECTION A–A
Ridges
Smooth
Power Supply Output Cord
A
A
3/16”
(5 mm) Max.
Figure 3. Power Connection
ATTENTION:
Do not tin the wires. For best results and to reduce the risk of short circuits,
trim just 3/16 inch (5 mm) of the jacket from the wires. If it is any longer, the
exposed wires may touch, causing a short circuit between them. If it is any
shorter, the wires can be easily pulled out even if tightly fastened by the captive
screws.
Always use a power supply supplied by or specified by Extron. Use of an
unauthorized power supply voids all regulatory compliance certification and
may cause damage to the supply and the end product.
Unless otherwise stated, the AC/DC adapters are not suitable for use in air
handling spaces or in wall cavities. The power supply is to be located within the
same vicinity as the Extron AV processing equipment in an ordinary location,
Pollution Degree 2, secured to the equipment rack within the dedicated closet,
podium or desk.
The installation must always be in accordance with the applicable provisions of
National Electrical Code ANSI/NFPA 70, article 75 and the Canadian Electrical
Code part 1, section 16. The power supply shall not be permanently fixed to
building structure or similar structure.
NOTE: Do not tin the wires. Tinned wire does not hold its shape and can become
loose over time.
b 3G-SDI Input — Connect an input device to the 3G-SDI input connector. The incoming
SDI signal is automatically detected and equalized.
Input equalization will allow signal transmission distances as follows:
SDI: Up to 1400 feet (426 m) using RG6 cable
HD-SDI: Up to 600 feet (182 m) using RG6 cable
3G-SDI: Up to 500 feet (152 m) using RG6 cable