CTL208CM Control Panel Module • Serial Communications
Serial Communications, cont’d
CTL208CM Control Panel Module
Command/response table for programming the CTL208 (continued)
C o m m a n d ASCII Command Response Additional description
(host to CTL208) (CTL208 to host)
A
Appendix
Reference Information
Specifications
Parts List
Front panel lockout
Disable front panel [FP0] [R0•
X1
FP0
]
Disable the control panel module buttons. If
programmed, timeouts function normally.
Enable front panel (default) [FP1] [R0•
X1
FP1
] Enable control panel module buttons.
Toggle front panel lockout [FP] [R0•
X1
FP
] Toggle front panel status (enabled-to-disabled
or disabled-to-enabled).
View front panel lockout [FP?] [R0•
X1
FP?
X15
]
Enable/disable responses
Enable serial responses [RES1] [R0•
X1
•RES1•
] Control panel module sends responds to serial
port commands.
Disable serial responses [RES0] {none}
Control panel module does not send responses
to serial port commands.
Control panel module reset
Reset control panel module [DFLT
X16
] {none} 0 = reset without reinitializing buttons,
1 = factory reset
Architectural information
View architectural information [ARC] [R0•
X1
ARC
X17
]
Display the control panel module model,
revision, and connection information.