4. In the Sync to Matrix panel, select Enabled from the Enabled/Disabled radio
buttons (see figure 86).
4
5
6 7
8
9
EDID
Sync-To-Matrix
Advanced Settings
Figure 86. Advanced Settings Page — Sync-To-Matrix
5. Use the Video Out field to enter the number of the matrix switcher video output port
connected to the SME100.
6. Use the IP Address field to enter the IP address of the matrix switcher connected to
the SME100.
7. Use the Telnet Port field to enter the Telnet port of the matrix switcher connected to
the SME100. The default is 23.
8. If a password is needed to access the matrix switcher connected to the SME100, use
the Password (if req.) field to enter the password.
9. Click the Submit button to save the configuration settings and sync the SME100 to the
matrix switcher.
NOTES:
If the SME100 successfully syncs with the matrix switcher, the Status field will
display Connected.
If the Status field continues to display Not Connected, check the settings of
the matrix switcher and the SME100 and try resyncing the devices.